A detection of concrete monolit strain zones
by the therminal infrared survey
S.G. Kornienko
Oil and Gas Research Institute the Russian Academy of Sciences,
Moscow, Russia
The potentialities of IR-survey as a nondestructive thermal monitoring of concrete monolits has been demonstrated with dam`s water-pape of hydroelectric station. The observations have reveled an area of anomalous thermal inertia, which may be linked to strain zone of concrete Layer. The results of a comparison estimation of moisture concent within concrete water-pape are given.